Skip to main navigation Skip to search Skip to main content

Measurement of off-flavoring volatile compounds and microbial load as a probable marker for keeping quality of pasteurized milk

  • Anjum Rashid
  • , Imran Javed
  • , Barbara Rasco
  • , Shyam Sablani
  • , Muhammad Ayaz
  • , Muhammad A. Ali
  • , Muhammad Abdullah
  • , Muhammad Imran
  • , Tanweer Aslam Gondal
  • , Muhammad Inam Afzal
  • , Muhammad Atif
  • , Bahare Salehi
  • , Célia F. Rodrigues
  • , Javad Sharifi-Rad
  • , Natália Martins
  • Washington State University Pullman
  • University of Veterinary and Animal Sciences, Lahore, Pakistan
  • The University of Lahore
  • Deakin University
  • COMSATS University Islamabad
  • Al Jouf University
  • Bam University of Medical Sciences
  • University of Porto
  • Semnan University of Medical Sciences

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

(1) Background: Multiple attempts have been conducted to correlate milk keeping quality with chemical, physical or bacteriological parameters. These methods only measure the chemical changes in milk produced by bacteria. Headspace solid-phase micro-extraction (HS-SPME) is an economic and recent method used to measure both volatile compounds and microbial load in milk, also allowing to keep the quality of the milk product. (2) Methods: The present study was conducted to identify and measure the off-flavoring volatile compounds through gas chromatography coupled with flame ionization detector (GC-FID) and the microbial load of pasteurized fluid milk stored at different temperatures, as a possible indicator of its keeping quality. (3) Results: The highest results were obtained to acetone, followed by butanone, pentanal and ethanol. These mean values were significantly enhanced from the 0 to 19th day of storage, at 10 °C. At day 19th, the minimum score for aroma, flavor and overall acceptability were also recorded as 4.33 ± 0.17, 4.02 ± 0.06, 4.00 ± 0.04, respectively. Likewise, maximum values for standard plate count (Log10 CFU 15.54 ± 0.40 mL -1 ) and total psychotroph count (Log10 CFU 11.67 ± 0.30mL -1 ) were reported at 10 °C and 4 °C. (4) Conclusion: HS-SPME/GC-FID methodology revealed to be very sensitive and capable to be applied in volatile compounds quantification in pasteurized milk produced during the storage period at different temperatures.

Original languageEnglish
Article number959
JournalApplied Sciences (Switzerland)
Volume9
Issue number5
DOIs
StatePublished - 2019
Externally publishedYes

Keywords

  • Microbial load
  • Off-flavoring volatile compounds
  • Pasteurized milk
  • Storage stability

Fingerprint

Dive into the research topics of 'Measurement of off-flavoring volatile compounds and microbial load as a probable marker for keeping quality of pasteurized milk'. Together they form a unique fingerprint.

Cite this